Preprint em Inglês | medRxiv | ID: ppmedrxiv-20235390

RESUMO

Clinical laboratories of the developing world are overwhelmed with RT-PCR SARS-Cov2 testing demands. It is of paramount importance that each clinical laboratory use an appropriate cut-off value in the interpretation of SARS-Cov2 real-time RT-PCR results, which is specific to their laboratory performances as ISO 15189 recommendations stipulate. We applied an indirect statistical method to a large mixed data set of Ct values (ORF1ab and N) to estimate cut-off Ct value ([~]32 cycles).we conclude that the use of indirect statistical approaches to estimate cut-off value in the interpretation of SARS-Cov2 real-time RT-PCR results may improve differential diagnosis of COVID-19 cases with low risk of infectivity, and may help to better estimates of the burden of COVID-19 disease.

3.
Preprint em Inglês | medRxiv | ID: ppmedrxiv-20171512

RESUMO

The RNA extraction is an important checkpoint for the detection of SARS-CoV-2 in swab samples, but it is a major barrier to available and rapid COVID-19 testing. In this study, we validated the extraction-free RT-qPCR method by heat-treatment as an accurate option to nucleic acid purification in Algerian population.